1. TRANSFORMER TURNS RATIO METER Transformer tu...

  • 2024-11-23T10:37:52

1. TRANSFORMER TURNS RATIO METER Transformer turns ratio is the ratio of the number of turns in the high voltage winding to that in the low voltage winding. Accurate Measurements of 1 Phase and 3 Phase Transformer / CT & PT Turns Ratio. Turns Ratio Range : 1 to 4000, 5 digit resolution (for transformers / CT & PT testing). Excitation Voltage & Current Range : 6 V AC, 250mA @ 50Hz (Other Range Available on Request) (Input: 230V @ 50Hz). Switch for Test ON/OFF, Hold, Parameters-1 & Parameters-2. Inbuilt Over Current Protection for Shorten Winding Test ON, Polarity Reverse & Measurement Hold Indication. 16 X 2 Jumbo LCD for viewing Parameters easily. Parameter to be Measured : Tr (Turns Ratio), mA (Excitation Current), HV (Applied Voltage in HV Side, LV (Measured Voltage in LV Side). Accuracy : ± 0.1% reading ± 0.1% range.. Accessories : Test Lead with Crocodile Clamp, Mains Cord, Instruction Manual. Compliance to ANSI/IEEE C57.12.90 and IEC 600076.1 (2000) & Other Standards.

1. TRANSFORMER TURNS RATIO METER Transformer turns ratio is the ratio of the number of turns in the high voltage winding to that in the low voltage winding. Accurate Measurements of 1 Phase and 3 Phase Transformer / CT & PT Turns Ratio. Turns Ratio Range : 1 to 4000, 5 digit resolution (for transformers / CT & PT testing). Excitation Voltage & Current Range : 6 V AC, 250mA @ 50Hz (Other Range Available on Request) (Input: 230V @ 50Hz). Switch for Test ON/OFF, Hold, Parameters-1 & Parameters-2. Inbuilt Over Current Protection for Shorten Winding Test ON, Polarity Reverse & Measurement Hold Indication. 16 X 2 Jumbo LCD for viewing Parameters easily. Parameter to be Measured : Tr (Turns Ratio), mA (Excitation Current), HV (Applied Voltage in HV Side, LV (Measured Voltage in LV Side). Accuracy : ± 0.1% reading ± 0.1% range.. Accessories : Test Lead with Crocodile Clamp, Mains Cord, Instruction Manual. Compliance to ANSI/IEEE C57.12.90 and IEC 600076.1 (2000) & Other Standards.

  • 2024-11-23T10:37:52

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us